H013 Chemical (flammable solvent)
Pacer Prepare It (preparation solvent) — hydrocarbon vapour inhalation, skin defatting, fire ignition risk, aspiration hazard if swallowed
Exterior wash — solvent prep
Inherent risk
12
L 3 × C 4 · High
Residual risk
8
L 2 × C 4 · Moderate
Existing controls
Apply to microfibre only (never panel); P2+OV respirator; gloves + eyewear; bay door open; no ignition sources within 3 m; flame-resistant cabinet storage
Additional controls
Quantity limits enforced; SDS confirmation pending — re-rate when classification confirmed; toolbox talk on hot-work exclusion
Ownership & review
- Owner
- Owner
- Last review
- April 2026
- Next review
- April 2027
Source: 02_Hazard_Risk_Register/Hazard_Risk_Register.xlsx.